  1. 155mm

    MEP-816B 60KW problem

    Is it for sale?
  2. 155mm

    MEP105A Gen Starts and dies

    First thing i can think, holding start switch in start position until oil pressure comes up
  3. 155mm

    M916 6x6 heights

    128” over horns, remove wheels 118”, remove wheels and steering tie rod 116” Truck would be sitting on diff pumpkin not on drums
  4. 155mm

    Mep-804a power output problems

    Start a new thread as to not hijack.
  5. 155mm

    MEP 804A shutting down

    803? You mean 804, right?
  6. 155mm

    Its cold outside lets talk Heaters, H81, H82, H83, etc.

    Did the viewing window clean up or does it still look dirty?
  7. 155mm

    Needing a starter switch for MEP 805A

    That thread zed posted above, tm 9-6115-644-10, adobe reader page 54, or tm pg 0005-4
  8. 155mm

    Needing a starter switch for MEP 805A

    You said the hz gauge only goes to 11 o’clock, are you sure the hz selector behind the gauge cluster is selected to 60 hz?
  9. 155mm

    Needing a starter switch for MEP 805A

    I wouldnt,, i would use conv plug, or load lugs. I prefer conv plug, it has juice all the time
  10. 155mm

    Needing a starter switch for MEP 805A

    I use an external voltage hz gauge as a backup that i plug in to convenience plug. Its not precise, but works to verify AC Multimeter 6in1 Combo Meter Voltage 110V 220V Current 100A Power Factor KWH Frequency Multifuction Tester...
  11. 155mm

    MEP 804A shutting down

    Take a video, and post
  12. 155mm

    Actual Rating for MEP-804B

    Bontonjeff, did you get the answers that you were looking for?
  13. 155mm

    Its cold outside lets talk Heaters, H81, H82, H83, etc.

    Decrease fuel pressure, after first test fire. better to have not enough than too much and flood the chamber sounds like it wasnt clean burning if the sight window was dirty
  14. 155mm

    Its cold outside lets talk Heaters, H81, H82, H83, etc.

    I think you are running wayyyyy too much fuel psi, try 90 psi or less. I am only running 70? Psi , ithink. Also i think max waste oil would be like 20% or less. I think I remember reading about waste oul use but don’t remember the number
  15. 155mm

    Its cold outside lets talk Heaters, H81, H82, H83, etc.

    Hanging the k8, was more of a cooling effect rather than a grounding issue. I drilled holes in one k 8 that was being problematic to manually operate the switch inside, but there was no need to manually operate it, it went to work and is working to this day in a body shop
  16. 155mm

    Actual Rating for MEP-804B

    Ok so single ph is 2 legs of 120v, 240v measured leg to leg. 3 ph is 3 legs of 120v, 208v measured leg to leg you can use a 3 ph generator to get single ph by using only 2 legs. But you will only have 208 v 804 805 806 are 10 wire generators therefore they cannot be reconfigured to a true...
  17. 155mm

    Actual Rating for MEP-804B

    10kw constant with 10% surge if you use 2 legs of a 3ph generator. 2/3 of rated capacity. the tm states you can use as single ph, use terminal 1 and 3.
  18. 155mm

    Actual Rating for MEP-804B

    The voltage reconnection board is only used for selecting required voltage...120/208 or 240/416
  19. 155mm

    Actual Rating for MEP-804B

    You can get 2 legs of 120v, but across both legs is only 208, not 240v. Generator will produce about 5 kw per leg, so single phasing a 3ph genny will only get 2/3 rated power