With a 12 volt system you can only jump 1 battery at a time on the 24 volt system. So you could jump one battery and let it charge for a while and then jump the second battery to see if it would start. Do not let the vehicles touch. Other than that you would need to jump it with another 24 volt...
Set of ramps, Houston,Tx to Ohio
Looking at trying to get a set of ramps from NDT in Houston, Tx. closer to ohio. 10 ft long, probably a couple hundred pounds each. No hurry.
My guess is that the new filter does not have metal caps? The metal caps are not supposed to be removable or re-used. Any pictures of the old and new filter?
3116 uses a piston pump in the governor housing. It has a check valve before the pump and a pressure relief valve where the fuel exits the front side of the head.
Yes. There is. Fuel from the tank travels to the little piston pump on the front of the motor. From there it travels thru the filter to the back of the head. It travels thru the head, under pressure, and fills the injectors. Any unused fuel travels to the front of the head where it passes thru a...