  1. M

    MEPs and Hurricane Irma

    I want to second that sentiment... and because we're going on 32 hours of enjoying the benefits of generated power you know it's sincere! :) -- Carl
  2. M

    MEP-803a : AirTex fuel pump substitution

    My 803 had a Facet 40193 primary fuel pump installed in it. I was having problems with it dragging down and shutting off after brief periods of load testing. I could not find the recommended AirTex E1074 anywhere. Replacement Facet pumps were over $200, that didn't seem like a good choice given...
  3. M

    Fuel Pumps and Fittings MEP-803a

    Since: My MEP-803a still has Facet fuel pumps. It has a probable fuel pump problem. The "official" replacements are hard to find. I'm going to try an AirTex E8131 for the transfer pump, and E8135 for the auxiliary pump. Plan to install AirTex inline filters ahead of both and will check...
  4. M

    MEP-803a: why different fuel lines?

    Thanks guys, good explanations! -- Carl
  5. M

    MEP-803a: why different fuel lines?

    I understand the hard line between ip and injector, but mine has hard line from fuel pump over to the fuel filters as well. It would be easier to run 1/4" hose, why is that part done with a hard line? -- Carl
  6. M

    MEP-803a: why different fuel lines?

    Preparing to replace my fuel lines and I'm wondering why there are hard lines and soft lines for the non-ip part of the circuit? If soft line is good enough for part of the run, why isn't it good enough for all of it? -- Carl
  7. M

    Fuel Pumps and Fittings MEP-803a

    Called AirTex technical support. The E11010 is 12V, but they do have two 24V pumps: E8131 10-14 psi E8135 5.5-9 psi Both are in the 14 gph free-flow volume range. AirTex sells on Amazon. -- Carl
  8. M

    Finally joined the MEP-803A club...

    Aha, found it! https://www.steelsoldiers.com/showthread.php?148791-MEP-802-and-803-Main-generator-tip Post #29 has the details. -- Carl
  9. M

    Finally joined the MEP-803A club...

    I just did the quad fuse modification on mine, where do I get the scoop on the MOV mod? -- Carl
  10. M

    How to look up Lister Petter parts numbers

    That's it, thanks Guy! -- Carl
  11. M

    How to look up Lister Petter parts numbers

    Yes, thanks, that is definitely helpful, good job reading my mind! :) I found a bunch of Lister Petter water pumps, but I want to know how to look up the numbers myself so I can order the right one the first time! So the manual for the 802a engine works for 803a parts? That probably explains...
  12. M

    How to look up Lister Petter parts numbers

    Lol, thanks Daybreak, I deserved that! :oops: I was thinking there was a separate technical parts manual for the engine, just like the generator. :) -- Carl
  13. M

    How to look up Lister Petter parts numbers

    Let's use the water pump as an example. -- Carl
  14. M

    How to look up Lister Petter parts numbers

    I understand how to use the technical parts manual to look up part numbers for my MEP-803a, but how do I find numbers for engine parts? Thanks! -- Carl
  15. M

    Too much of a good thing, MEP-803a wouldn't stop!

    Yep, that's what happened! -- Carl
  16. M

    803a load testing questions

    I'll check that, thanks for the suggestion! -- Carl
  17. M

    Too much of a good thing, MEP-803a wouldn't stop!

    No binding at all... the linkage totally disconnected, leaving the fuel shutoff in the "run" position. Manually moving the fuel shutoff to the "off" position stopped it. -- Carl
  18. M

    Too much of a good thing, MEP-803a wouldn't stop!

    Good idea, that's where I was headed when I spotted the linkage problem. That might have done it, but something was keeping the fuel pump going with the other two switches off, so maybe not... -- Carl
  19. M

    Too much of a good thing, MEP-803a wouldn't stop!

    I set out to change filters and fluids this morning and decided to run the unit briefly to make sure everything worked beforehand. It started up and ran just fine, as expected. Then I turned the master switch to off... and it kept running! :shock: After taking this in for a few seconds I...
  20. M

    803a load testing questions

    Ok, got some more data today... Ran with an 80% load for about 15 minutes before it shut down with the same behavior as before: the rpms rapidly drop and the unit comes to a stop with the oil pressure light on. While it was running I monitored the temperature at the fitting for the top radiator...