Check my YT channel username Rronmar. Did a vid on the typical primer issue and resolution. Not sure which port you pulled on the primer assembly, but that may keep it from working... 16-18 pumps to lift fuel from tank to primer with an empty line, ~20 more)with full filters) to feel...
well if brakes work while hazards do not, relay K-10 switches between the two, and since it energizes when brakes are applied, if it is a 5 pin relay(has de-energized contacts), that would point me toward the flasher assembly.
You can simulate flasher input by disconnecting its connector and...
You might think it a noob clue, but there is no such thing. Observation is observation…
Ok, the only relay indicators that would flash with Hazard or turn are the trailer light relays that switch 24v to power commercial 24v trailer lighting, K30 and K31.
You say the green LEDs flash but does...
Strength would be a bigun…
the rod end side of the piston(side used to lift the tire) has ~ 2.36 sq/in of surface area. It takes ~2200PSI to lift the tire, so that is 5,183# of force from the cylinder to lift the tire…
Ok, as mentioned, grounding, or light sw, or flasher unit, or TS switch on the column Or hazard sw in the dash as it provides all power to the flasher…
next time it happens note if relay K9 is energized or de-energized. It gets its power from the light switch via CB74 and it provides the power...
@Primussucks thinking about this a little further the behavior you described leads me to believe that filler plug you show a picture of is not vented, if it is pushing fluid out the gap between housing and reservoir. if the pump and reservoir are designed to handle a certain amount of...
only if everything continues to work perfectly. Any air leakage around the control or the rod end when it pulls a vac will mess with you. Thats why hydraulic systems are typically not designed to rely upon vacume, and only positive pressure displacement…
The A1R uses data bussed gauges driven by a box called the MMDC, so adding another gauge would be difficult. You would probably have better success switching between two separate tank level senders... This sender switch function is usually incorporated in the tank switching function on...
2" piston has an area of 3.1416 sq/in. 35cu/in = only 11 inches of cylinder travel.... Now if the rod end has fluid in it returning to the reservoir as the cab raises, that should give you enough fluid to lift the cab.
Depending on the pump internal plumbing and seals, as you lower the cab...
Well if the vent is clear working , any overflow should be coming from there, not where the pump body meets the reservoir…. Take it completely off and try it…
What is the volume of the pump reservoir
does the pump have an air vent/filler port? That is what PP was getting at, the oe pump does not have a vent either as the plumbing directs fluid to the hand pump up to about 5 psi to keep it full, then sends the rest to the air op reservoir which IS...
There is a page elsewhere in the diagrams that has a more detailed PDM1 diagram that should show the connector and pin for 12v batt in and out. Like the drawing pic you posted shows that accessory output connector and pin, P101-E.
I am thinking that access is more like accessing the wiper linkage. Since it is in the front skin, It is forward of the dash, heater and power panel assemblies.