  1. J

    need help with 003A

    i have an MEP 003A that runs strong and carry a resistive load fine but it won't start the ac condenser unit. the main breaker trips instantaneously. i installed a soft start on the unit but it made no difference. i read the whole thread about the main breakers and have done a little work to...
  2. J

    will a 1.5 kw 28VDC generator jump start an 003A

    will the 1.5 KW 28VDC generator charge and jump the 002a 003a generators?
  3. J

    another 002A DC Voltage regulator question

    had a little ice storm this week and had to get the 002A out of the shed. it has been running perfect in every way until now when i start it up and check the battery charge all is fine at 26.2 volts for about 10 min then it creeps up to 33 volts. could this be a ground issue? or is the DC VR...
  4. J

    off topic Kubota lowboy GL11000

    there is a local to me Kubota GL11000 either a 10K or 11K series II generator for sale pretty cheap. the owner says he had the unit in storage no mice. and when he started it to give it a monthly run the battery light flashed and the big gen quit producing power. has anyone here any experience...
  5. J

    Mep 015a

    needed some mobile electric power today to run a grinder and cut off tool. picked up the baby 015A put it in the back of the UTV and off to work. ran for about three hours and got the job done. gotta love the baby generator
  6. J

    MEP 802a battery charging question

    the gauge on the control panel on my 802a always registers a few amp and is overcharging the battery's. my question is the voltage regulator on the battery charging alternator adjustable or do i need to just replace it? Thanks
  7. J

    Mep 802A temp question

    i have been fooling around some with my 802A with 4400 hours. when i start it and run it for about 8 to 10 minutes with no load the coolent temp will read about 140 with ambient temp about 70 degrees F. oil temp is about 100 and both exhaust ports checked with a laser thermometer are real close...
  8. J

    is anybody parting out an MEP 802A??

    i need a wire harness?? the one that has all of the connections from the cannon plug to the engine compartment. THANKS
  9. J

    802A were does your battery charge needle rest

    on an 802A were is normal for the battery charge needle with fully charged and low battery???
  10. J

    how much does an MEP 802A weigh?

    Thanks does anyone know how much an MEP 802A weighs
  11. J

    having an ice storm

    yup having a couple days of freezing rain. really not much build up yet but the power is blinking. maybe gonna have to get the 002A out of the shed.:-)
  12. J

    MEP 802A-803A sticky

    now that i have joined the ranks of 802A-803A owners i have been searching for more info and mods/procedures and the other owner observations and remedy for this series of generators. i vote for a STICKY that we can use to quick find some for the new owners. please
  13. J

    looking at an 802A with 4000 hours

    I am looking at an 802A with almost 4000 hours on it everything works and it produces power. any advice as what to look for? what would you pay for such a unit. it looks complete no dents and the rain flap is still there. just an average looking 802a
  14. J

    thinking of GL auction

    was thinking of replacing my 002A with a newer unit from GL. anyone know what they are going for aprox? any advice? i have never done the GL auction before. what about shipping?
  15. J

    J10 plug on 003A

    can someone confirm for me that the J10 plug on the lower control box on an 003a is the two wires that carry 24 VDC to the generator to excite the generator?
  16. J

    will my mep 003a run with the fuse pulled 24 vdc

    my 24 VDC regulator is overcharging the batteries. can i run the generator with the fuse pulled? will it discharge my batteries with the fuse pulled?
  17. J

    Mep 003A Mep 002A DC charging volts

    I am shopping for some new batteries for my MEP 002A and 003A generators. I have found that the AGM type battery out perform flooded lead acid battery especially when just sitting. they don't discharge as fast and have more capacity than the lead acid battery. the only problem i have found is...
  18. J

    lttle copper washers

    do you use the little copper washers when you replace the glow plugs on an MEP 002A or MEP 003A ? or any other engine for that matter. Thanks
  19. J

    how many KVA is my MEP 002A

    I am no expert so let me know if i figured this correct. to figure the KVA of my MEP 002A i first took 240 volts x 26 amps x 1.732 constant then divided by 1000 240x26x1.732 divide 1000 =10.80 so my little 002a is 10 kva? right?
  20. J

    MEP 002A control box vibration dampeners

    I think i need some new Vibration dampeners for my MEP 002A. the control box shakes more than it should. i temp fixed the problem by doubling over some soft rubber tarp straps and wedging them between the box and frame. anyone know who carries these parts?