• Steel Soldiers now has a few new forums, read more about it at: New Munitions Forums!

  • Microsoft MSN, Live, Hotmail, Outlook email users may not be receiving emails. We are working to resolve this issue. Please add support@steelsoldiers.com to your trusted contacts.

 

Search results

  1. A

    MEP-804B Overvoltage Shutdown

    Thanks Guyfang! I assume the troubleshooting points to it since you didn't comment on it? Just wana make sure im not searching so hard for something that isnt bad :)
  2. A

    MEP-804B Overvoltage Shutdown

    Thank you very much!!!
  3. A

    MEP-804B Overvoltage Shutdown

    Can someone please chime in. There has to be somewhere that has these in stock. Any help is greatly appreciated.
  4. A

    MEP-804B Overvoltage Shutdown

    So the unit was running and then suddenly it shut down. No black smoke on crank so i figured its a no fuel issue. Ive troubleshot it but maybe im missing something. Here is everything i did. - checked the mpu, getting 3.004 ish volts on crank. - There is power coming from the Governor to the...
  5. A

    MEP-804B Overvoltage Shutdown

    Thank you for all the help finally got it running but after a few hours have a new issue. Seems like my governor actuator is burnt/out, where could I find a replacement. Cant seem to find one online. Maybe its just me but can anyone tell me where I can find one?
  6. A

    MEP-804B Overvoltage Shutdown

    Here are the results of the A1 and pot tests... h. range is 4 to 12 vdc, I'm getting 11.2 volts j. range is 110 to 160 VAC, I'm getting 158 VAC I. it says I should get no more than 2 ohms at full CCW position however mine goes no lower than 4 to 5 ohms. Ohms increases rather smoothly however...
  7. A

    MEP-804B Overvoltage Shutdown

    Guyfang thank you for jumping in. Sorry stupid question, how do i reset? Below I will post the results of the test of A1 and the voltage pot seperately.
  8. A

    MEP-804B Overvoltage Shutdown

    Just realized didnt answer the first part, it is not "known" to be good. It may very well be the culprit. Thanks for all your help. I will report results of the test later on today.
  9. A

    MEP-804B Overvoltage Shutdown

    I have the TM just not sure what the -24 is. I plan to do the voltage regulator tests today. I will report the results.
  10. A

    MEP-804B Overvoltage Shutdown

    Great, any ideas how i proceed?
  11. A

    MEP-804B Overvoltage Shutdown

    Thanks. Here it is. Red, black, gold, gold.
  12. A

    MEP-804B Overvoltage Shutdown

    Side note, the transformer was preinstalled, so thats what i used to verify that its a trc vs the libby.
  13. A

    MEP-804B Overvoltage Shutdown

    Yes i verified with a chart i found online. 20k ohms potentiometer, TRC transformer, i guess i havent verified the R16 resistor. Am next to it now, how would i tell?
  14. A

    MEP-804B Overvoltage Shutdown

    The set is new to me. I received it without the A1 voltage regulator. It is the TRC model btw.
  15. A

    MEP-804B Overvoltage Shutdown

    Hi. First off I want to say that this site is amazing and I found a wealth of information on here so thank you everyone for that. I have a MEP-804B built in 2010. Upon start it gives over voltage error and shuts down. With the A1 completely disconnected it runs fine with the under voltage light...