  1. NDT

    Power Distribution Panel M1083A1 10/98

    I don't understand your question. Each FMTV only has one "PDP" Power Distribution Panel. Year models 1994-mid 1998? (M1078/1081 etc) had the "Blox" style; the late 1998-2002? M1078A1/1081A1 etc had the printed circuit board type (pictured), and the final version is the "Bussman" type which...
  2. NDT

    Power Distribution Panel M1083A1 10/98

    You are quite correct, there are 3 versions of the PDP (power distribution panel) that were used on the FMTVs, this is the second generation, and is considered the worst due to the soldered connections being lead free. The manuals for the FMTVs uploaded to this site do not cover this PDP as far...
  3. NDT

    Power Distribution Panel M1083A1 10/98

    is this what you have?