  1. R

    Mep-003a/002a

    No the issue is not the actual breaker it's the number of winds of wire going through the current transformer. The difference in winding affects the ammeter reading and the functionality of the breaker ( it's not your typical thermal style breaker ) it is possible to take 1/2 the loops of wire...
  2. R

    Mep-003a/002a

    They are interchangeable but diffeerent It will physically fit but the CT has a different number of wire loops through it, so the ammeter won't read correctly. I also used to believe the AC circuit breaker was different, but recently heard that the breaker is in fact the same. So bottom line, it...