    240hippie replied to the thread No AC output MEP-802A.
    Standing on the trailer while this is running is, well my feet feel funny. A1 to A2 (0-VAC) B1 to B2 (2.5- VAC, C1 to C2 (24.9-VAC)...
  • 2
    240hippie replied to the thread No AC output MEP-802A.
    So, When I took K1 apart. It has some small burn spots (tiny) on the 3 pull down contacts. Cleaned. I took the bottom off and the inside...
  • 2
    240hippie replied to the thread No AC output MEP-802A.
    Yes. It is a sliding lock out, and not the cheap China one. This is USA made.
  • 2
    240hippie replied to the thread No AC output MEP-802A.
    The lock out is a mnaul type. You have to turn off the Main for the house before you can turn on the breaker for the gnerator.
  • 2
    240hippie replied to the thread No AC output MEP-802A.
    Okay, I already took it off completely. No improvement. Still nothing on the voltage gauge. Hertz is running 60 on the nose. The light...
  • 2
    240hippie replied to the thread No AC output MEP-802A.
    Okay, so just remove it. Right
  • 2
    240hippie replied to the thread No AC output MEP-802A.
    I attached a pic, is that the bonding strap??
    • 20250430_095043.jpg
  • 2
    240hippie replied to the thread No AC output MEP-802A.
    Okay brother, were is TB1 ?? I have found TB2 which is the lug panel. Also when I find TB1, what am I looking for and what do I do?
  • 2
    240hippie replied to the thread No AC output MEP-802A.
    I only have the generator supplying 120V. So it is a 3 wire. I was just informed about the bonding strip on TB1 by a dude in Germany. I...
  • 2
    240hippie replied to the thread No AC output MEP-802A.
    Real Deal hook up. I will check TB1. AWG8 wire, twist lock plugs, lock out on breaker box. There always seems to be a "reference TM". I...
  • 2
    240hippie replied to the thread No AC output MEP-802A.
    I know nothing about a bonding strip. Were would this be and what do I do to disconnect.??? The K1 had a couple tiny burn dots on the...
  • 2
    240hippie replied to the thread No AC output MEP-802A.
    Just used it fo r my house on an outage for 7 hours. Have done alot of maintenance. Repairs when 1 st purchased of course. Mostly...
  • 2
    240hippie replied to the thread No AC output MEP-802A.
    The hertz gauge is working and set at 60. Everything is working properly except the AC output. It was a month ago, it powered the house...
  • 2
    240hippie replied to the thread No AC output MEP-802A.
    802a, looked thru all of you pdf's, have a manual down loaded. Not very helpful. My 802a was working just fine a month ago, had a power...
  • 2
    240hippie replied to the thread No AC output MEP-802A.
    802a, looked thru all of you pdf's, have a manual down loaded. Not very helpful. My 802a was working just fine a month ago, had a power...