    aw113sgte replied to the thread Hand pump overflow.
    After raising the cab all the way, I've been able to use the tire hoist just fine, indicating enough fluid. Maybe I do have air bubbles...
  • A
    aw113sgte reacted to Ronmar's post in the thread Hand pump overflow with Like Like.
    Or you could partially restore the added volume of the original 2 reservoir system. Reconnect the line on the manifold valve circled in...
  • A
    aw113sgte reacted to Ronmar's post in the thread Hand pump overflow with Like Like.
    well you said after it burps a time o two, it wont have enough fluid to raise the cab again right? Since the reservoir is at least 5oz...
  • A
    aw113sgte replied to the thread Hand pump overflow.
    I'm really not following. It has more than enough volume to raise the cab, so when lowering, that same volume should return to the...
  • A
    aw113sgte replied to the thread Hand pump overflow.
    Not for when the AOP is removed.
  • A
    aw113sgte replied to the thread Dearborn adapter woes.
    Sure, I should have been more clear, some websites post download links to files that are pirated.
  • A
    aw113sgte replied to the thread Hand pump overflow.
    Reservoir volume is .6 liters (20.3 fl oz) I am able to tilt the cab and lower the spare, then raise the spare and start the cab coming...
  • A
    aw113sgte reacted to Ronmar's post in the thread Hand pump overflow with Like Like.
    and with the AOP lines capped, and it the only pump in he system, it would have to be vented... back to the basic premise, this system...
  • A
    aw113sgte replied to the thread Hand pump overflow.
    Yes, hand pump is vented to atmosphere with the specified venting cap from the manufacturer. Yes AOP lines are capped.
    • 17132977591851574424358762140304.jpg
    • 17132978545883565070413385147056.jpg
  • A
    aw113sgte replied to the thread Hand pump overflow.
    From the diagram, it sure looks like it should pull from the reservoir. Even if the return pickup is high, it should pull fluid before...
    • 1713290010971.png
  • A
    aw113sgte replied to the thread Dearborn adapter woes.
    With the exception of CTIS they are all paid software so links cannot be posted on the forum.
  • A
    Tires: inspect for weather cracking and make a judgement call. Cracks on the sidewalls are a no-go. Minor surface cracking on the...
  • A
    aw113sgte posted the thread Hand pump overflow in FMTV.
    Had this problem for a while now, with two different pumps. When lowering the cab (allowing gravity to do it slowly - no pumping on the...
  • A
    aw113sgte replied to the thread Dearborn adapter woes.
    Based on what the validator shows, yes it looks like he does. I have had very good luck with this adapter on various computers and...
  • A
    aw113sgte replied to the thread From fire truck to MTV.
    Got the batteries, a bit over 15 kWh. 300lbs so was considering where to place them to keep passenger/driver level but habitat corners...