Ray70's latest activity

  • R
    In the picture above you would spin that gen around and slide it backwards more, remove the front tool box and put the other 802...
  • R
    Hi Digger, I've done that with 2 802's on that trailer before, but not side by side. I mounted the forward one sideways and the 2nd...
    • power plant trailer.jpg
  • R
    Ray70 reacted to Tinstar's post in the thread MEP-002A Saved the Day with Like Like.
    The MEP-002A was called into duty during and after a Historic wind and wildfire breakout in Oklahoma a few days ago. Towns evacuated...
  • R
    Ray70 replied to the thread Mep 006A won't turn over.
    The procedure to test the Main load contactor CB2 is on page 3-71 of the -12 operator and organizational maintenance manual. If you find...
  • R
    Ray70 reacted to Guyfang's post in the thread Mep 006A won't turn over with Like Like.
    OK. The AC output Contactor is CB2. The Switch to turn on and off, the CB2 is S3. The light that is suposed to come on, when the CB2 is...
  • R
    Ray70 replied to the thread Mep 006A won't turn over.
    The TM has a page that lists all the reference indicators and what they are. It's important to become familiar with these references...
  • R
    Ray70 replied to the thread Mep 006A won't turn over.
    Look on ebay under Stanadyne 24371 injection pump kit. Price ranges from $25 to $40 The 2 black rubber umbrella seals in that kit are...
  • R
    Ray70 replied to the thread Mep 006A won't turn over.
    If you have a Home Depot nearby, for $28 you can get a Kill-A-Watt meter that will plug into the 120V courtesy outlet, it will...
  • R
    Ray70 replied to the thread Mep 006A won't turn over.
    The kit to rebuild the IP is like $30 for the basic kit, or a little over $100 if you go with the upgraded metal governor weight basket...
  • R
    Ray70 replied to the thread MEP-006A.
    You're not producing electricity by the looks. Looking at your meter I believe you only have 334 millivolts, not 120 , 208 0r whatever...
  • R
    Ray70 replied to the thread MEP-006A.
    I don't see any pictures, did you intend to attach a pic. of you measuring voltage? It sounds like you ARE getting voltage at the lugs...
  • R
    Ray70 replied to the thread MEP-006A.
    Can you further explain where and how you are measuring voltage? Are you seeing voltage at the courtesy outlet? And you get nothing on...
  • R
    Ray70 replied to the thread Are 6TL Batteries worth it?.
    My first and only experience with LiFePO4 was pure disappointment, possibly due to my lack of knowledge about them. I've got a john...
  • R
    Ray70 replied to the thread Mep 802a.
    Do the tests and determine if the issue is the gage, or most likely its the sending unit in the tank. If it's the sending unit, there...
  • R
    Ray70 replied to the thread Heat Pump Soft Start.
    What size is your heat pump and what did you use for a soft starter?