• Steel Soldiers now has a few new forums, read more about it at: New Munitions Forums!

  • Microsoft MSN, Live, Hotmail, Outlook email users may not be receiving emails. We are working to resolve this issue. Please add support@steelsoldiers.com to your trusted contacts.

Testing ac VR mep002/003

Dog Breath

Active member
Steel Soldiers Supporter
78
109
33
Location
Wisconsin
I have a Vr board from a oo3 I believe that I have no idea if it is good. Would it hurt anything to install it in a working 002 to see if it is any good? I know very little about the electrical side of things.
 

kloppk

Well-known member
Steel Soldiers Supporter
2,229
3,870
113
Location
Pepperell, Massachusetts
You could certainly try it.
If needed, I have a test setup that can test them per the TM. If it fails I can troubleshoot and most likely repair it.
Just finished up troubleshooting and repairing 7 of them last week.
Failures I encountered were bad Q3 transistors, some bad Q1 and Q2 transistors, bad diodes and some burned up resistors due to transistor faiures. One had a damaged potentiometer due to a stupid OEM assembly error.
 
Top