• Steel Soldiers now has a few new forums, read more about it at: New Munitions Forums!

  • Microsoft MSN, Live, Hotmail, Outlook email users may not be receiving emails. We are working to resolve this issue. Please add support@steelsoldiers.com to your trusted contacts.

Search results

  1. D

    Meter's on Mep002 not working.

    For synchronous generators, it is simple. If the gen head is a two pole, it needs to go 3600 to give 60Hz. If the gen head is a four pole, it needs to go 1800 to give 60Hz. ..............six pole..................1200....................................... A MEP-016B head, for example, has 3...
  2. D

    Meter's on Mep002 not working.

    OK. But, less than rated RPM (1800?) is not good for VR, or so I'm told. If you get an accurate 60Hz then you are probably right on RPM.
  3. D

    Meter's on Mep002 not working.

    Isn't that one of the gens you should not run at anything other than full throttle? The HZ meter should not read 60 unless you are at proper output RPM. Or, is 1/2 throttle giving you 1800RPM?