Steel Soldiers now has a few new forums, read more about it at: New Munitions Forums!
Microsoft MSN, Live, Hotmail, Outlook email users may not be receiving emails. We are working to resolve this issue. Please add support@steelsoldiers.com to your trusted contacts.
Thanks Guyfang! I assume the troubleshooting points to it since you didn't comment on it? Just wana make sure im not searching so hard for something that isnt bad :)
So the unit was running and then suddenly it shut down. No black smoke on crank so i figured its a no fuel issue. Ive troubleshot it but maybe im missing something. Here is everything i did.
- checked the mpu, getting 3.004 ish volts on crank.
- There is power coming from the Governor to the...
Thank you for all the help finally got it running but after a few hours have a new issue. Seems like my governor actuator is burnt/out, where could I find a replacement. Cant seem to find one online. Maybe its just me but can anyone tell me where I can find one?
Here are the results of the A1 and pot tests...
h. range is 4 to 12 vdc, I'm getting 11.2 volts
j. range is 110 to 160 VAC, I'm getting 158 VAC
I. it says I should get no more than 2 ohms at full CCW position however mine goes no lower than 4 to 5 ohms. Ohms increases rather smoothly however...
Guyfang thank you for jumping in. Sorry stupid question, how do i reset? Below I will post the results of the test of A1 and the voltage pot seperately.
Just realized didnt answer the first part, it is not "known" to be good. It may very well be the culprit. Thanks for all your help. I will report results of the test later on today.
Yes i verified with a chart i found online. 20k ohms potentiometer, TRC transformer, i guess i havent verified the R16 resistor. Am next to it now, how would i tell?
Hi. First off I want to say that this site is amazing and I found a wealth of information on here so thank you everyone for that.
I have a MEP-804B built in 2010. Upon start it gives over voltage error and shuts down. With the A1 completely disconnected it runs fine with the under voltage light...
Hi. What was the final resolution to this? I have a 2010 built MEP-804B with the MWO. I get overvoltage light instantly and it shuts off. Is it for sure A1 or should I also be looking elsewhere before ordering a replacement? Any steps for determining if A1 is bad?
Sure, ad-blocking software does a great job at blocking ads, but it also blocks useful features of our website like our supporting vendors. Their ads help keep Steel Soldiers going. Please consider disabling your ad blockers for the site. Thanks!