  1. T

    MEP803a no crank

    Thanks guys, I have found the problem after reading here more. The s1 switch was missing the jumper that connects 8 and 4 together. I connected a jumper wire in between and it fired right up! Aloha.
  2. T

    MEP803a no crank

    Yes Emergency Stop is pulled. Dead crank in normal, and fuel pump run. I should’ve added that. Sorry. the only way it would start is when I use a jump wire to jump it from x1 and a1 at the k2 relay.
  3. T

    MEP803a no crank

    Hi new member and first post here. But I’m usually here reading threads for other equipments. MEP803 Generator will start when jumped from K2 using a jumper wire, it cranks at the dead crank but will not start. I will not crank at the master switch (S1). Also already swapped s1 switch just...