Do you suggest changing the regulator since one of the rectifiers as bad? I already ordered both rectifiers. Also did all the other tests according to the TM and they all came out good on the generator. Just seems to be a bad positive rectifier. Beats spending almost $800 on the generator lol.
Ok I switched multimeters and got better results. About 12.5 ohms on connections 3,5,6 on the + rectifier and on 4 almost no reading. So guess I will replace the positive rectifier.
Following the directions below, I was diagnosing the rectifiers on my generator that is not charging. It appears that my positive rectifier is bad, but the readings I am getting on my multimeter do not match what they are saying in the instructions below. It says between 20 and 30 ohms for a 1.5...