• Steel Soldiers now has a few new forums, read more about it at: New Munitions Forums!

  • Microsoft MSN, Live, Hotmail, Outlook email users may not be receiving emails. We are working to resolve this issue. Please add support@steelsoldiers.com to your trusted contacts.

Search results

  1. C

    Mep 803a not powering past 25%

    I will look into that. Thank you for the response. If I’m not getting the proper voltage what would be the issue? The regulator?
  2. C

    Mep 803a not powering past 25%

    throttle is set in normal position and the Hertz gauge is reading 60. And the back panel switch is in the 240v single phase
  3. C

    Mep 803a not powering past 25%

    I have an MEP 803a I recently bout with 500 hours. I am running a camper that has two A/C units on it and it’s only running half of the camper. The output needle will not exceed 25%. My multimeter shows 240v and the receptacle is showing 140v but for whatever reason it’s not increasing the...
  4. C

    Low voltage on MEP 803a

    Hello all. New to this group with some experience with military generators. I recently purchased an MEP 803a from gov planet. 2007 with tier 2 reset done in 2011 with 220 hours. The unit is only producing 50-60 volts on the L1 & L3 lugs. If I flash the field it produces the normal 220v 60 hz As...
Top