  1. cvh20

    M35A2 transmission problem

    Someone requested more pictures, here is what I can find
  2. cvh20

    What happens when you hit a "speed bump" in your deuce....

    The front was locked in, but in Low 3 the tires were spinning too fast. I dropped down to Low 1 and it was just right to crawl out. This is a disturbed earth pile and not compacted well, so it is hard to get traction.
  3. cvh20

    Frustrated with idle

    I had a similiar issue with idle dropping too low. Turned out to be previous operator had changed the length of the rod that connects to the gas pedal and it was too long (and binding below the pedal). It was beyond just adjusting with the screw adjuster so it took me a while to figure out that...
  4. cvh20

    How to go about preparing waste oil for use.

    I am not sure of the real cost of the racor setup, I got mine for free off an old used generator....
  5. cvh20

    How to go about preparing waste oil for use.

    I have the double filter system shown above and it works great. I run the oil through a regular oil filter, then through these filters. Only difference is mine each have the clear centerfuge cup on the bottom so you can drain off the water.
  6. cvh20

    Broke your motor from WMO?

    I'm with MikeW, mine doesn't smoke much more than with straight diesel. I am running about 80% WMO, run through three filters in series and two water seperators.
  7. cvh20

    Phase Angle Meter (Power Factor Measurement)

    Shovelmike, I hear ya and I agree. But the original poster was asking if they come stock on the generators or should he add one. For whatever reason on a civilian generator, you will almost never see power factor meter on a single phase generator, only a three phase generator. I think it is...
  8. cvh20

    neutral bonding at the generator

    I design, sell, and install standby generator systems for a living.....been through this many a time with Mr. Building Inspector
  9. cvh20

    Phase Angle Meter (Power Factor Measurement)

    If they are single phase, they won't register anything on the power factor meter.
  10. cvh20

    neutral bonding at the generator

    The key to the whole seperately derived system nomenclature is "are you switching the neutral when you transfer to the generator". If you do switch to an isolated generator neutral like coyote62ny just described, you have a seperately derived system. If you connect your generator neutral to your...
  11. cvh20

    Phase Angle Meter (Power Factor Measurement)

    These gens three phase?
  12. cvh20

    Transmission yoke removal

    Some of these pictures may help. They show it taken apart. http://www.steelsoldiers.com/deuce/70653-m35a2-transmission-problem-5.html
  13. cvh20

    Stupid question time: How to post to classifieds?

    Thanks for the info, I was wondering the same thing.
  14. cvh20

    Sig Test

    Good test :shock:
  15. cvh20

    What did you do to your deuce this week?

    Mounted my Go Pro camera in the windshield. Sound isn't too great because the passenger window closed unexpectedly and was blowing air across the camera.
  16. cvh20

    Compressor going bad?

    Mine is the same way, quiet when pumping, but sounds like a ping pong ball bouncing around when the tank is pressurized. Check valve of some kind maybe? I also noticed mine is lacking the filter completely. Anyone have a picture of what the filter looks like? Thanks
  17. cvh20

    Multi Fuel engine on propane?

    Propane or natural gas is commonly used in big diesel generators to conserve fuel and make the diesel tanks last longer. It is fairly expensive option though.
  18. cvh20

    Having trouble starting my deuce

    It was hard nasty rust. The bottom of the tank was rusted where water was sitting in there. It was only about a quarter full of fuel so the other three quarters were small chunks of rust on the sides just from moisture/condensation over a long period of time. I scrapped it best I could and...
  19. cvh20

    Uses for Deuces

    Hauling equipment