• Steel Soldiers now has a few new forums, read more about it at: New Munitions Forums!

  • Microsoft MSN, Live, Hotmail, Outlook email users may not be receiving emails. We are working to resolve this issue. Please add support@steelsoldiers.com to your trusted contacts.

 

Search results

  1. J

    MEP-003A Will Not Start - Need Mechanic- Chicago Area

    ***<PROBLEM SOLVED!!! --- UPDATE 10:42 PM 4/8/2012>*** Well the misses and the family are all ticked off because I missed Easter Dinner, but I got it working! Here's what I found: I was studying and taking notes from the IP sections of the TM (longest section if you ask me) before removing...
  2. J

    MEP-003A Will Not Start - Need Mechanic- Chicago Area

    Injector Problem? .... or still Governor issue? Speedmon, Using the TM and some help I found on other postings/threads, armed with a Fluke Digital Multi Meter, I adjusted every which way on the rachet and the linkage for the governor. I did not adjust my max and min speed as this seem to...
  3. J

    MEP-003A Will Not Start - Need Mechanic- Chicago Area

    Ranchhopper, I'm located in Chicago, IL: Near North Ave & Western. I have the unit on a trailer and could bring by after the holiday if you have some experience with adjust the governor. Having a hard time maintaining speed under varying loads.
  4. J

    MEP-003A Will Not Start - Need Mechanic- Chicago Area

    UPDATE: 4:08 P 4/7/12 Yesterday I had a mechanic come over to check the unit and see if he could unlock the hydrolock or check the problem. The glow plugs looked too dangerous to remove so we removed the injectors one by one. The tops of the cylinder were visiblee with a little light and...
  5. J

    MEP-003A Will Not Start - Need Mechanic- Chicago Area

    THOUGHT! One thing I forgot to mention, the other mechanic broke the plastic linkage that attaches the governor to the fuel injector pump. He had a wire holding open to full throttle! I removed this wire cable and replaced the plastic linkage with a metal one that I found on another post, that...
  6. J

    MEP-003A Will Not Start - Need Mechanic- Chicago Area

    Here's what I've tried so far: I removed the starter and tested directly to the battery. Both the new and old spin and actuate the gear into position. Both seems to be operating. The new one seems a little smoother versus the old one. I greased the gears and shaft that it slides on the...
  7. J

    MEP-003A Will Not Start - Need Mechanic- Chicago Area

    Update to the Starter Wiring: I have confirmed that we have the wiring done correctly. It was difficult, but following the schematics we found the cannon connector and traced the leads back to the proper terminals on the solenoid switch and starter. --------------------------- Now we're at...
  8. J

    MEP-003A Will Not Start - Need Mechanic- Chicago Area

    Hi Jim, Yes, I can hear and physically see that switch pull in and allows the fuel switch to move in relationship to the mechanical or spring governor. Main problem as you'll see in my previous post is that the mechanic may have wired the starter in correctly as it was not labeled. I can't...
  9. J

    MEP-003A Will Not Start - Need Mechanic- Chicago Area

    Update: Spoke with Coyote62 (thanks for calling ;) and he offered some tips which we will try. I'm at the point where we are going to try working on it ourselves. The previous mechanic removed the starter without labeling any of the leads coming from the battery or control box. I looked at...
  10. J

    MEP-003A Will Not Start - Need Mechanic- Chicago Area

    We have an MEP-003A generator and we are looking for a mechanic that has experience with these anywhere near Chicago. We've tried a diesel mechanic who can't seem to figure out and we've been chasing our tails with this thing. First we were told it was just air in the fuel lines, then the...
  11. J

    Mep 002A governor linkage broken.

    Once you changed for the metal style, were you able to adjust and get it to idle correctly?
  12. J

    MEP-003A with PLC controlled auto start

    Picture of Connections I have the PLC on order you're using in the video. It seems you just tapping off the multi-switch connections and wiring this to the terminals on the PLC. Can someone please post a picture of how you did this internally, just to make sure I'm going about this the right way.
Top