• Steel Soldiers now has a few new forums, read more about it at: New Munitions Forums!

  • Microsoft MSN, Live, Hotmail, Outlook email users may not be receiving emails. We are working to resolve this issue. Please add support@steelsoldiers.com to your trusted contacts.

Search results

  1. D

    Generator Hours - How high have you seen on 002 or 003

    I've got one with 2292 hours on it that I just got. Everything on it seems orignal except for a splice in the aux fuel float and somewhere near the IP. I may have put on an hour of that during startup, testing and putting loads on and it works well so far. My other one isn't fully...
  2. D

    need help trouble shooting a mep002

    I would check all fuel lines, fittings and filters to make sure they're not drawing air. Remove and reseat them all to make sure they are seated correctly and tightly. Do the same for the oil filter. Check fluid levels and then put in run/prime until the clicks slow down. Check if fuel is...
  3. D

    MEP-002a overvoltage, bad transformer

    Thanks for answering so quickly. I'll take a closer look at the transistor. Since I have 2 units I will probably try a board swap and see if the problem follows the board. What will the symptoms be of an open on C1-C2 on the CVT? the one on the 'bad' mep still shows an open across them...
  4. D

    MEP-002a overvoltage, bad transformer

    Hello, I'm new here and have learned tons from lurking and researching over the past 2 months. I recently bought 2 MEP-002a units from Warner Robins and it's been a learning experience. The good news is I already have one working 100%. The bad news is, the other I am having some issues with...
Top