• Steel Soldiers now has a few new forums, read more about it at: New Munitions Forums!

  • Microsoft MSN, Live, Hotmail, Outlook email users may not be receiving emails. We are working to resolve this issue. Please add support@steelsoldiers.com to your trusted contacts.

Search results

  1. B

    MEP 003A Misfiring

    Hey Everyone: With full batteries, the unit ran smoothly for a couple hours under 50% load. The low voltage was obviously the culprit. I will be running the test procedures prescribed in TM-05684c/05685B-12, pages 4-29,30 & 31 over the weekend. Thanks to jamawieb for the link to the voltage...
  2. B

    MEP 003A Misfiring

    I charged the batteries overnight and will run the unit today. Will let you know what happens. Thanks everyone for the comments.
  3. B

    MEP 003A Misfiring

    Hey Guys: My MEP 003A is in use approximately 16 hours per week. When I started it up today, it had developed a slight misfire. The missing was progressive and occurs more under load. It might be notable that the battery gage is now pegged at discharge. It went from green to yellow and is...
  4. B

    MEP 003A - Low Voltage on L1 & l2 when set in 120/240 Volt position

    Yea Ray. You're right. You never know when you will need something to work like it is suppose to. My Dad always said "Safe ain't sorry" thanks again all.
  5. B

    MEP 003A - Low Voltage on L1 & l2 when set in 120/240 Volt position

    Hey All: I just can't thank you guys enough for your comments and advice. Ray, you hit it on the nose. The L1 and L2 wires from the main breaker to the reconnection switch were both connected to the L2 terminal. I moved the L1 wire to the L1 terminal and the generator is now producing 120/240...
  6. B

    MEP 003A - Low Voltage on L1 & l2 when set in 120/240 Volt position

    Sorry All: I had some interruptions. According to the operator's manual, the Voltage Rheostat on the control panel adjusts the voltage output. But that is not what I believe to be my issue. When I switch the Reconnection Switch to the 120/208 3Ph position, L1-L0, L2-L0 and L3-L0 all test close...
  7. B

    MEP 003A - Low Voltage on L1 & l2 when set in 120/240 Volt position

    I have a recently purchased MEP 003A. The genset starts and runs sufficiently, however I can only get 28-30 volts on L1 & L2 when the Reconnection Switch is set in the 120/240 Volt position but 115 Volts from the L3-L0. When the switch is set in the 3Ph position, the voltage from L1-L0, L2-L0...