  1. M

    MEP 005A single phase conversion question

    All of the wires are labeled. I had to twist a few of the wires to see the label but they were there. I got 120V across L0-L1, L0-L2, and L0-L3. Then 240V across L1-L3.
  2. M

    MEP 005A single phase conversion question

    I found a loose connection on a re-check. It all works fine now. 120V on each leg and 240V across legs.
  3. M

    MEP 005A single phase conversion question

    MEP-005A Conversion to Single Phase: I went through the procedures and all the wires were marked per the procedure. The only difference was that the copper bus bar was under the terminal board with the rest of the wiring rather than on top. It was also riveted to the terminal board. Made all the...