  1. RGJ58

    MEP-003 recovery and adventure

    I learned it from you sir! Thought the least i could do is pass it on!
  2. RGJ58

    MEP-003 recovery and adventure

    Here are two quick pictures I took tonight to show you how the after market Yokogawa 254350AJ-AJ9 gauge looks in the panel. Tomorrow I will open the control box and show you how it is wired, its very simple.
  3. RGJ58

    MEP-003 recovery and adventure

    I had the same issue your did so I removed the transducer plus the old gauge and installed one of these analog hertz meters. Yokogawa 254350AJ-AJ9 is the part number and manufacturer it is a direct drop in for the original hole in the panel. Note that this gauge requires AC current to be wired...
  4. RGJ58

    My MEP003a story and Hertz issue

    OK i would like to say thank you to everyone who has helped me along the way in solving the various problems with the Mep003a that i bought. As well as sorry that it takes me so long to reply but work has been rough! I know that i seemed to have solved the issue with my Hertz gauge by...
  5. RGJ58

    My MEP003a story and Hertz issue

    I received this very quality built looking regulator from triple Jim and proceeded to install and wire it up. I was happy to see that the regulator came with installation instructions as that is very helpful for a generator newbie like me! I know my multi-meter is a cheapo! However it would...
  6. RGJ58

    New guy checking in with M923A2

    Welcome! From Mobile, AL, Thank you for your service!
  7. RGJ58

    My MEP003a story and Hertz issue

    I did not have time to go out and work on the unit today but i would like to thank all that posted a reply. I was not aware that the voltage regulator was missing but it makes sense now as i could not find out where it was located. I also thought it was odd that you had wires going to no where...
  8. RGJ58

    My MEP003a story and Hertz issue

    Hello all thank you for your responses as well as i would like to give a special thanks for SS member Guyfang for his continued help. It appears to me that someone went through my generator set and disabled a bunch of key systems. After knowing what i know now about the frequency transducer i...
  9. RGJ58

    My MEP003a story and Hertz issue

    Yes i checked that fuse only to find it had previously been cut out of the circuit as both wires had been cut through. I couldn't get a good look in there though i need to take that front cover off to see why some moron would disable the fuse. Along with that i found another wire cut clean...
  10. RGJ58

    My MEP003a story and Hertz issue

    So I installed a new Yokogawa Hertz gauge on the 003a this afternoon it was a exact drop in replacement. I would like to thank SS member Harleyd315 for providing me with the correct part number of 254350AJ-AJ9. However with the good always comes far greater bad of course so once i connected the...
  11. RGJ58

    My MEP003a story and Hertz issue

    Yeah it was a rookie mistake i will admit, It was my fault i did not do the proper research on it. From what i can tell yokogawa makes a contained unit that looks very similar to the gauges that come on the civilian Onan DDYJ versions i would be perfectly happy with that. I saw a older post...
  12. RGJ58

    My MEP003a story and Hertz issue

    Today i had a short time to work on the generator and i discovered a few things that are a bit disheartening. First off i connected the mep017a Hertz gauge that i purchased online to the existing wires were the factory mep003a hertz gauge connected and i got no reading at all. My digital multi...
  13. RGJ58

    My MEP003a story and Hertz issue

    That is a very good idea! That's impressive!
  14. RGJ58

    My MEP003a story and Hertz issue

    Hello all I am sorry it has taken me so long to update the thread things have been crazy out here and I haven't had much time. Thank you all for all the helpful replies I appreciate them! I have not gotten a chance to mount the after market fuel solenoid to the unit yet but will let everyone...
  15. RGJ58

    My MEP003a story and Hertz issue

    (ChainBreaker) That sounds great i briefly looked on eBay to see if i could find that seller to purchase one of the gauges but could not find them. Would you happen to have Jim C's seller name or a link to his products? Also i have seen those kill-A-watt meters in videos of MEP003a online and...
  16. RGJ58

    My MEP003a story and Hertz issue

    Hello all, SO.... Here is my MEP003a story, Before i dive off into it i would like to say that i have done much searching and this site has helped me fix all of my issues up till this point so thank you steel soldiers! I purchased a MEP003a off of ebay for a what i thought was a good...
  17. RGJ58

    Mep 003 Batteries

    I simply use used no name group 59 batteries and they have been good to me so far on a Mep003a
  18. RGJ58

    New guy from Mobile AL

    Thank you all for your replies and yes this site was already a great resource even before i signed up. I appreciate all those that take the time to upload all that information for others to benefit.
  19. RGJ58

    New guy from Mobile AL

    Hello all, I have been following this site without signing up for some time now and i will say it is a great resource! I just recently bought a MEP003a generator and i have been having some issues getting it running so i thought to myself well now is the time to sign up.
Top
AdBlock Detected

We get it, advertisements are annoying!

Sure, ad-blocking software does a great job at blocking ads, but it also blocks useful features of our website like our supporting vendors. Their ads help keep Steel Soldiers going. Please consider disabling your ad blockers for the site. Thanks!

I've Disabled AdBlock
No Thanks