  1. A

    803 Pre-heat run-away

    The same thing happened to me with the junk blue S-1.. purchased 2x of the better ones from a member here and s***canned the old ones. I’m sure I could’ve sold them on eBay but I wouldn’t do that to somebody
  2. A

    Question about picking up mep802a with trailer from GP.

    Along with the harbor freight lights a lot of zip ties most of the trailer is aluminum so you’re going to want to secure the magnetic light with zip ties and all the wiring to it because it’s extra long. I try to have one of them pressurized air tanks and tire gauge in case they can’t help me...
  3. A

    mep-802a fuel level sender float

    I had bad fuel pump out of 2006 subaru outback that I had replaced at one time. I harvested the float cut it to length and it's installed and working. The old float was just some kind of light weight composite not hollow. cost $0
  4. A

    mep-802a fuel level sender float

    did not notice any.. I thought it was just a lightweight composite / plastic. Did not realize it was hollow like the old metal ones. When I get a chance I'll slice it down the middle and take a look.
  5. A

    mep-802a fuel level sender float

    my fuel gauge read "E" so I followed the TM and pulled the sending unit and it Ohm'd out to specs. I reinstalled it and ordered a new fuel gauge. I get the new gauge installed and it's and still on "E". I next ohm'd it in place with a full tank and it's reading 216 ohms = near empty. I made...
  6. A

    mep-803a dc side shorted to ground

    the red emergency push button. Yes it works now.
  7. A

    mep-803a dc side shorted to ground

    Found 2 cut wires shorting to ground behind the gauge panel.... I thought I had found and taped them all up. Don't understand why they cut wires for no obvious reason.
  8. A

    mep-803a dc side shorted to ground

    I just picked it up from gp as is. only has 200 something hours on it. When I connect the battery it arced at terminal had some burning smell and smoke coming from behind the gauges. I disconnected battery and started troubleshooting. When this happened it tripped the breaker behind the 110v...
  9. A

    re-wiring my MEP-004a for different voltages, including single phase

    Matt have you converted any of the Drash 3 phase units to single phase full rating? I have a isuzu powered 20kw 3 phase and was curious. It has a marathon magnaplus 12 lead head with se350 controller. I'm changing it to zigzag 120/240 now. Thank you in advance. Albert