Gentlemen ,
Hold on to your hats .
Yesterday i talked to the previous owner of the generator ,
i bought from him with a bunch of other stuff like fork lifts , backhoe loaders
i ask him if there was a time the generator was working fine
and yes it always worked fine until the same problem we...
Hello Guy ,
the ac jumps between 160 / 180 volts ,
is there a diagram how to pump suppose to be on the inside ,
so when i take it apart i can check if it is correct ,
maybe the person before me did not installed the richt way
when i just lossen the bracket that holds the pump it starts...
Hello Guy and Ray ,
it runs on all 4 cil but not the rpm it need to run nice ,took the metering pump out ,and let it soak in break clean for a day or so
or can i take it apart it looks like it has some marks on it from tools
and i can move the rack there are 3 shims sins nobody fooled around...
Hello Guyfang and Ray ,
i did remove the muffler no change stil smoking , when i loosen the metering pump it wil pick up and runs on al 4 cil
i let it run for an hour or so even with a 50 % load it is still smoking more then normal
output is good 220 v and 110 v 60 Hz
when i shut it down it...
Hello Ray ,
i did not use the cans of starting fluid for starting i did a bit of cleaning work on the injectors ,
when i had them out ,no brake clean or carb clean on site .
and i was in the marine corps for 8 years so send Guy over whahaha .
the reason the machine is or was idling so low is...
Hello Ray,
so fare i found out that it is the cilinder closes to the radiator ,
even after changing the top injectors it still was not running on al 4 cil
all metering pumps are in the same position ,
when i crack open the line coming from the pump diesel is sputtering out so it getting diesel...
Hello Ray ,
thanks for the quick response ,
So i switched the injectors on the cilinder Head no change
when i crack the line direct from the metering pump there is a small change little more rpm
but not enough to pul it to run on all 4 cil ,i think the metering pump is not working correctly...
Hello ,i have a mep 803a with about 1000 hours on it ,
it starts up rough i have to adjust the fuel injector and then it picks up and runs great black smoke
i had it under load and still runs good still black smoke but not as much ,when schutting down it taks a while it sputters and rumbles...