• Steel Soldiers now has a few new forums, read more about it at: New Munitions Forums!

  • Microsoft MSN, Live, Hotmail, Outlook email users may not be receiving emails. We are working to resolve this issue. Please add support@steelsoldiers.com to your trusted contacts.

Search results

  1. D

    002a voltage regulator

    Electronic parts arrived yesterday for my 002a's A4 board and VR. Installed resistors and diode, put both in the working 002 and I had voltage and it was right where it should be. Both boards are working! Great! Now to get the fuel side up to par... Thanks for everyone's input. David
  2. D

    002a voltage regulator

    Thank You!
  3. D

    002a voltage regulator

    No ohm reading on A4 R1-resistor broken in the middle. Got A4 board out and all diodes check out ok. Found numbers on the R1 on my working unit (V560, CM-5-5, and CV8124). Mouser has a wide range of resistors. Anyone know where I could find the wattage value? Should I just overkill and go...
  4. D

    002a voltage regulator

    Does the R1 need to be un-soldered for measurements or can it be done in place? Thanks, David
  5. D

    002a voltage regulator

    Ok, back from quality time with the grand kids..... I let the machine shop finish the compression adapter for the injector attachment. Pictures below. Had machine shop drill a 1/8" diameter hole through center for gauge access. Tested the adapter on a working 002 and got 385 psi dry and 430...
  6. D

    002a voltage regulator

    All-thinking about this.... I knew I had seen it somewhere. TM34, dia 7-10.1 shows an injector adapter to check compression. Point on the gaskets is well taken. Appreciate the feed back. Thanks, David
  7. D

    002a voltage regulator

    All, My bad on not asking. Thanks, David
  8. D

    002a voltage regulator

    1800 diesel-talk about not seeing the forest for the trees.... I never thought about taking the injectors out and then trying them..... Oh well. Triple Jim-Thanks for the follow-up. Electrical side is on the back burner until I get the engine running. Stopped by a machine shop this AM and...
  9. D

    002a voltage regulator

    Hard starting 002a Kevin, Appreciate the response: 1. Prior to starting, you are holding the preheat switch for 45 seconds, right? I'll assume your response is yes, since you stated the starting problem also occurs when the engine is hot. Yes, I have preheated for up to one minute. Also...
  10. D

    002a voltage regulator

    Triple Jim, The only piece that looks burned is R11. Still working on getting the engine running. Starts hard (even hot). Have to use starting fluid (sparingly). Once it gets up to starter dropout, I get some smoke and then it takes off. Have had the ip apart several times and everything...
  11. D

    002a voltage regulator

    Working on sorting out electrical problems on a 002a and have a burned R11 resistor (1/2 watt, 330 ohm), on the voltage regulator. Is this an indication of Q2 also being taken out? Voltage goes high when board is installed in a working unit. Thanks David
Top
AdBlock Detected

We get it, advertisements are annoying!

Sure, ad-blocking software does a great job at blocking ads, but it also blocks useful features of our website like our supporting vendors. Their ads help keep Steel Soldiers going. Please consider disabling your ad blockers for the site. Thanks!

I've Disabled AdBlock
No Thanks