Here's the thread with pictures of the alternator
http://www.steelsoldiers.com/index.php?name=PNphpBB2&file=viewtopic&p=102135&highlight=#102135
If I understand the TM it should have between 26 and 30 volts which is what I have at 29 volts. It still worries me because the meter in the cab is...
TM 9-2320-280-34 states for no load test(follow my copy and paste):
Amps-28 VDC-14VDC as follows below:
81-100 21-25 10.5-12.5
Test bench battery is discharged (or defective).
Allow to charge (or replace).
81-100 26-30 13-15
Give time to stabilize while monitoring VOLTS...
Well I checked my voltage on my dual voltage alternator (or is it generator?) and the high side is 29 volts and the low is 14.5. I think I am about to blow up my batteries. The volt meter on the inside of the truck is at the edge of the red.