You need a good 10-20 amps for a 24 hour period to charge each battery. You need to do this individually. Once they all have a decent charge then you can put them into the trucks normal hookup pattern and slow charge them the rest of the way.
You can get a small slave plug and connect it to a 24v trickle charger. I have small ones like this that work well they have a 10 or so foot cable already attached.
Those are not agm batteries. You have to measure the voltages at the alt regulator and the outputs of the alt. Its a common issue for the regulator wires
to go bad and you will have a low voltage issue. You have to run new wires to the regulator if thats your issue.
Hawkers need a deep 20-30 amp charge for 24-36 hours. They may not appear to start taking a charge for several hours. Once charged you can get a trickle charger to maintain them with agm feature.