    MEP Sizing Help

    My 805B has those vari-sistors on the bottom side of the terminal board.
  2. 155mm

    MEP Sizing Help

    Guy, you can unlike the last post, I have edited it.
  3. 155mm

    MEP Sizing Help

    I thought he was talking about maintenance, service, and load testing, not producing power for consumption. When I am load testing/troubleshooting, I always bond N and Ground, and then ground the genny and the trailer to the outside ground. If I am load testing, then the load tester gets a...
  4. 155mm

    MEP Sizing Help

    I dont use my shop electrical ground, I have a dedicated grounding rod outside the shop just for generators. The reason being I wont use my shop ground is, if by chance something goes fubu and a 805B throws 300 amps of power the wrong place, then my whole shop gets 300 amps of power thru all...
  5. 155mm

    MEP Sizing Help

    Also plan enough time to go thru the uncle sams retail outlet store that is there. You might need to bring a bigger trailer than planned
  6. 155mm

    MEP Sizing Help

    I dont think that mod will work on an 804, they are only 10 wire generators, must use an 004, its a 12 wire head
  7. 155mm

    MEP Sizing Help

    I]
  8. 155mm

    MEP Sizing Help

    This one isnt a 15kw, but it was military. csheath, is this what you were looking for? it is in an enclosure, the enclosure is an old minute man missle control box. This is will be my backup when it gets all wired up. We would have used it for a snow storm but I only had the cable in the...
  9. 155mm

    MEP Sizing Help

    I lnow he said he wanted a 80x, bit whats wrong with an oo4 with the single ph mod
  10. 155mm

    MEP Sizing Help

    I am guessing that a 15kw will be better suited. By his description it sounds like an older all electric home, and my guess is an older well motor with no soft start ability so the well by itself pegs a needle about 4k on a start. I think he would be gobbling up a 10k and running the chance of...
  11. 155mm

    MEP Sizing Help

    We were out of power for 6 days, I used a 804a for all of our stuff here, never exceeded 50% capacity. My fuel consuption was 6-7 gallons a day, running 8 hours a day. here is the link http://www.steelsoldiers.com/showthread.php?167498-Wife-is-now-a-green-iron-believer