  1. Suprman

    Can Nordic hvac units be run on shore power

    One of the GA ones? That look almost new? Nice units they crank. Only issue is they are all R22 refrigerant which is expensive. If its charged then you are good. If not you can probably find a hvac guy to charge it with nu22.
  2. Suprman

    Can Nordic hvac units be run on shore power

    I have a 5 ton Nordic unit I use. I have played with the smaller ones but I don't have anywhere to install them. One day I may have a specific use though. The 5 ton unit is duct it's easier to adapt. I run that off an 803a. Only takes around 4000 watts when running. The older 5 ton AC units need...
  3. Suprman

    Can Nordic hvac units be run on shore power

    They use 407c which is cheap. A lot of the older units use r22. Which is being phased out and is stupid expensive.
  4. Suprman

    Can Nordic hvac units be run on shore power

    MS3106F18-11S should be the correct plug. Same connector at the TQ generators use for paralleling. But the paralleling cable is not rated for the power draw of the AC unit. Nice little unit though. I have one.
  5. Suprman

    Can Nordic hvac units be run on shore power

    Post a pic of the unit and data plate. I have some of the manuals. The connectors can be ordered it's not hard to make the cable.
  6. Suprman

    Can Nordic hvac units be run on shore power

    If it's a 120/208 unit and you have that correct 3phase power then yes. The military stuff is usually wye configuration with 3 120v legs to neutral and 208 between the legs themselves.