  1. General Hood

    HMMWV Fan Clutch Demons - Please Advise

    There is a diagram in TM-2320-280-20-1 unit maint. in the steering control system section
  2. General Hood

    HMMWV Fan Clutch Demons - Please Advise

    Verify and double verify the plumbing is correct, anything hooked up wrong or backwards in the system will cause this problem, however, in my case it was a faulty component (cadillac valve).
  3. General Hood

    HMMWV Fan Clutch Demons - Please Advise

    Yes, didn't see any other way. I labeled or color coded everything I removed, which helped when putting it back together. If any of your cooler hoses show signs of cracking or age, it would be a good time to replace. At the advice of Infidelgotme, I double clamped all the cooler hoses when...
  4. General Hood

    HMMWV Fan Clutch Demons - Please Advise

    After replacing most everything in the system ( lines, cooler, Cadillac valve, temp sensor, time delay module, PS pump, fan clutch 3 times , it ended up being Cadillac valve. The second NOS unit fixed my problem . I have a good sized area in and around my driveway grass will probably never grow...
  5. General Hood

    HMMWV Fan Clutch Demons - Please Advise

    Yes I changed out the pump with a NOS unit, but the problem persisted prior to the pump swap. I was hoping the new pump would have fixed the problem, but no
  6. General Hood

    HMMWV Fan Clutch Demons - Please Advise

    Today, I plugged the line from the Cadillac valve to the fan clutch. Performed the TM method of bleeding the system ( just to confirm no air in the lines) Cranked it up and immediately a rupture occurred in the line from the Cadillac valve to the cooler. PS fluid sprayed from here to kingdom...
  7. General Hood

    HMMWV Fan Clutch Demons - Please Advise

    While contemplating my next course of action, I disassembled the original fan clutch expecting to see a bad o ring or ???? But the 2 o rings on the spindle and one o ring in the dust cup look to be okay. Nothing to implicate why a deluge of power steering fluid would blow by
  8. General Hood

    HMMWV Fan Clutch Demons - Please Advise

    I will look into the pressure tester. I don't want to end up with a garage full of formerly NOS fan clutches trying to overcome this obstacle
  9. General Hood

    HMMWV Fan Clutch Demons - Please Advise

    Confirmed visually
  10. General Hood

    HMMWV Fan Clutch Demons - Please Advise

    Arrow points to where the PS fluid blows out, behind dust cover
  11. General Hood

    HMMWV Fan Clutch Demons - Please Advise

    Yes, same ports they were removed from.
  12. General Hood

    HMMWV Fan Clutch Demons - Please Advise

    Negative! No foaming over, no milky looking PS fluid. The fluid is blowing out of the fan clutch
  13. General Hood

    HMMWV Fan Clutch Demons - Please Advise

    I had posted a while back that my Cadillac valve was not functioning so I bought a NOS replacement from a fellow SS member. Once replaced and system bled, upon start up the fan clutch blew PS fluid everywhere. I replaced the fan clutch, bled the system and again another fan clutch sprays PS...