    MEP803a Auxiliary Fuel Operation

    So I figured the fuel gauge was up to no good as far as it's readings were concerned. Traced it to a faulty fuel sender. Replaced the fuel sender with a KUS USA SSS/SSL slide sender which I got from Dusky Marine. http://www.duskyonline.com/WEMA-p-fuel-senders-withdraws.html#prod-chart The old...
  2. I

    MEP803a Auxiliary Fuel Operation

    I treated the diesel with Stanadyne Lubricity and added Power Service BioKleen Biocide when I filled the one 50 gal tank. I have a diesel subcompact tractor which will be cycling the fuel and the tank will be topped off and the other one filled before the start of hurricane season. I strap the...
  3. I

    MEP803a Auxiliary Fuel Operation

    I have read through the TM and Operator manuals for the 803 and could not find a clear answer on the operation of the auxiliary fuel supply function. I was fortunate to have received the supply line with my unit when I bought it at auction and I purchased the jerry can adapter to go with it. I...