    Output issues with MEP701A - Power outage issue.

    I did some digging (kinda hard to find info on the 701a) and it does have a voltage adjustment knob. It's the second one from the left (the left being the voltage selector for the gauge)
  2. nextalcupfan

    Output issues with MEP701A - Power outage issue.

    He means what voltage do you have the Voltage Adjust knob at. You should be able to set the output to anything from 220-250V
  3. nextalcupfan

    Output issues with MEP701A - Power outage issue.

    The 701a is a 3kw generator (de-rated a bit from the military). You asked 16A or 16A per leg, since 16A at 240 is 3840 Watts I'm going to go with 16A Total. A 5kw MEP-802a is rated for 26A at 240V for comparison. I think you only add the amperage together for 3 phase power.
  4. nextalcupfan

    Output issues with MEP701A - Power outage issue.

    From what I've heard motors can have an in-rush current 2x or even 3x of the "Nominal" run rating. For Example (keep in mind this is a tad extreme) This A/C unit's LRA is 64A while the RLA is 12.8, that means the in-rush is 5x the run rating. Now normally this isn't a big deal because the...