• Steel Soldiers now has a few new forums, read more about it at: New Munitions Forums!

  • Microsoft MSN, Live, Hotmail, Outlook email users may not be receiving emails. We are working to resolve this issue. Please add support@steelsoldiers.com to your trusted contacts.

Search results

  1. WillWagner

    M35a2 hard start when cold surging hunting and smoking

    Just clear tubing from Home Defect works. Do it on the supply line to the booster pump. Any pressure will rupture the hose. You can check for air in the low pressure system by installing a shut off valve, like a WOG valve in the port where the bleeder is on the secondary fuel filter. On the...
  2. WillWagner

    M35a2 hard start when cold surging hunting and smoking

    If it starts and runs, it will bleed itself. No reason to bleed after it runs. It IS possible to introduce "air" into the system from a weak pintle spring. The compression overrides the pintle spring in the injector and lets compression INTO the fuel system. It will usually shut an engine off...
  3. WillWagner

    M35a2 hard start when cold surging hunting and smoking

    Or possibly a giant restriction. There is a filter located under the alternator, did that get changed. Also, the hard fuel line that runs from the tank, to the filter under the alt and across the front of the frame, has a tendency to get crushed. That can cause restriction issues. Also, ef you...
Top