According to the fuse block picture I have (from this site) the engine control fuse should be 20A.
The fuse is good, are you getting power to the fuse?
Are both of those green wire connectors at the IP plugged onto spades or is one disconnected?
It appears that you do not have a fast idle...
I am in the -20 TM. Appendix F, Page F3 Engine Compartment Circuits.
There is a fast idle solenoid that has the LT GRN-936B wire running to the cold advance control where the wire LT GRN-936A runs to the cold advance and fast idle temperature switch.
Form the temp switch there is the...