  1. Guyfang

    Mep-803a motor locking up at 0 and 180deg

    Drive you to drink!
  2. Guyfang

    Mep-803a motor locking up at 0 and 180deg

    After you have removed and replaced injector pump a few times, its much easier. Just try and never remove them all at once.
  3. Guyfang

    Mep-803a motor locking up at 0 and 180deg

    That's because the milatary would not try and fix the injector. They would simply replace it. Just try soaking it for a few days.
  4. Guyfang

    Mep-803a motor locking up at 0 and 180deg

    You are not supposed to be able to turn the S17 on and then start the set. If you can se the fuel rack, and it will not move when you manually move the linkage, there is your problem.
  5. Guyfang

    Mep-803a motor locking up at 0 and 180deg

    Don't forget, you put fluids in the jugs to loosen things up. So unless you are sure that stuff is all drained out, spin it over a bit with the S10 switch. Just short shots at first. If it sounds good, then try an start it.