  1. J

    Mep 804 b having mpu issues

    I did reinstall mpu , turned in until it contacted the flywheel then backed off 1and 1/2 rounds connected multimeter, checked with multimeter. It showed 0 volts a.c. and 752 ohms
  2. J

    Mep 804 b having mpu issues

  3. J

    Mep 804 b having mpu issues

    I went back and checked the mpu disconnected with the volts meter, I got 0 volts a.c. , I then checked the ohms and got 726. I then pulled the mpu out and checked the ohms and got 732, while it was laying on the fender.
  4. J

    Mep 804 b having mpu issues

    I rechecked the new aftermarket mpu , the highest ohms , I could adjust to was 226 ohms and 0 volts ac. I then reinstalled old mpu , and was only able to get 752 ohms and 0 volts ac. I will try checking a.c. Volts with the mpu disconnected in the morning. I really appreciate the help with this...
  5. J

    Mep 804 b having mpu issues

    Thanks for the input, loosegravel, I was following the directions in the TH .
  6. J

    Mep 804 b having mpu issues

    It is the TH , I disconnected 147c from terminal 16 and 148c from terminal 17, of the governor control unit. Then connected multimeter set to ohms, my highest reading was 776 ohms and 1 VAC. I then bought an aftermarket MP U and installed, my highest reading was only 286 ohms.
  7. J

    Mep 804 b having mpu issues

    As per instructions , I disconnected 147c from terminal #16 and 148c from terminal #17, it only adjust to 776 ohms, it needs between 800 and 900. I bought an aftermarket mpu and it will only get to 286 ohms. Any suggestions ?