  1. Suprman

    GETT 23kw 120000btu - Applied Companies

    The electric heater isn't enough to overcome fridgid temps. They are probably getting hot. If you have air closed circuit recirculating thru a tent eventually it will start to warm it. It won't take in cold outside air and blow it out hot.
  2. Suprman

    GETT 23kw 120000btu - Applied Companies

    Gotta get into that schematic and see what sensors are involved. Maybe the the cold start bypasses some of the sensors.
  3. Suprman

    GETT 23kw 120000btu - Applied Companies

    If you don't have voltage to the actuator the engine cannot run. Actuator is the fuel solenoid. It retracts with voltage so the fuel rail can move open. That's why if you remove the actuator the fuel rail will move full left and it will run. The system varies the voltage to the actuator to...
  4. Suprman

    GETT 23kw 120000btu - Applied Companies

    You can take the fuel solenoid out and it will run. When you crank on normal setting there should be voltage at the actuator contacts. The speed controller varies the voltage to control engine speed vs load so you can't just apply voltage and expect it to work. Gotta look at the schematic in the...
  5. Suprman

    GETT 23kw 120000btu - Applied Companies

    Not really.
  6. Suprman

    GETT 23kw 120000btu - Applied Companies

    Make sure the signal is making its way to the governor module. For some reason the governor isn't opening the fuel solenoid if there is only voltage at the solenoid when you crank on cold start. Could be a bad connection somewhere. Could be the governor. The manual doesn't have step by step...
  7. Suprman

    GETT 23kw 120000btu - Applied Companies

    The manual isn't good for much. Usually screw the sender in till it touches the back off 3/4 turn. You can put a multimeter on ac and crank it. See if you get a few volts.
  8. Suprman

    GETT 23kw 120000btu - Applied Companies

    Maybe the speed sensor magnetic pickup.
  9. Suprman

    GETT 23kw 120000btu - Applied Companies

    Did you clean out the fuel pump catch? Could be a bad fuel pump. On high idle it's enough to overcome it.
  10. Suprman

    GETT 23kw 120000btu - Applied Companies

    Look for cracked fuel lines. Maybe getting air in somewhere.
  11. Suprman

    GETT 23kw 120000btu - Applied Companies

    Leave it on normal and see if you have voltage at the governor fuel solenoid coil conmection.
  12. Suprman

    GETT 23kw 120000btu - Applied Companies

    Cold start kicks the rpms up higher than normal start. Can mask other issues that will prevent normal idle. Does it do anything in normal start mode? Did you completely drain the fuel tank and put a new fuel filter on. And replace any cracked lines? Fuel pump is mechanical. Round thing side of...
  13. Suprman

    GETT 23kw 120000btu - Applied Companies

    Bad fuel pump. Hole in the diaphragm.
  14. Suprman

    GETT 23kw 120000btu - Applied Companies

    No only the 30s and 60s. I haven't seen any of the 15k kits around.
  15. Suprman

    GETT 23kw 120000btu - Applied Companies

    Manuals are in the tm section. Did you drain the fuel tank first and change the filters? Cold kicks the rpms up. Check for dry rotted fuel line too. Once you get all that done and some fresh fuel in there chances are it will run better.
  16. Suprman

    GETT 23kw 120000btu - Applied Companies

    Ok. The gett gens are Applied. Drash is hdt. I got the hvac manual from Applied. They said they didnt have the gen manual. I prefer the Drash gens they have really good support too. The Applied ones can be had for alot less than the Drash.
  17. Suprman

    GETT 23kw 120000btu - Applied Companies

    I have the hvac manual I need the gen manual. Use sheet metal size adapters so you can use what mil ducting you can find even if the size is not an exact match.
  18. Suprman

    GETT 23kw 120000btu - Applied Companies

    You can go to your local hvac supply house they can make sheet metal adapters so you can fit different size ducting.
  19. Suprman

    GETT 23kw 120000btu - Applied Companies

    These have maybe a 1/4 inch hole for wire. If you want to crimp them it has to be with the proper aero terminal crimper. If then terminal pins get out of round they wont fit in the hole. The torch would be overkill for this.
  20. Suprman

    GETT 23kw 120000btu - Applied Companies

    I have the smaller hand crimper it wont do those big pins. You have to lay out the whole assembly with cable. Dont want to get it partially together and then see you forgot a piece and have already started soldering. I used really thin 60/40 solder. Thinner the better. Need something to hold the...