  1. chucky

    Charging/Maintenance and Alternators

    If you isolate each bank of batts/each charging system / with a shut off switch so you can test each section by metering the ground side of your cables till you find the one that has a draw to find your culprit
  2. chucky

    Charging/Maintenance and Alternators

    You should have anything your using when the main engine is off only pulling from the house batts so you never run down your way home batts. and worse case start the truck every once in a while that alt will charge all batts up much faster just remember to flip the switch off that ties the 2...
  3. chucky

    Charging/Maintenance and Alternators

    My solar charger stops input wattage if it senses more voltage from any other source then goes back to charging when the other source stops charging to protect itself and you need to have a battery temp sensor on the house batteries that shuts down your charger if they get to hot
  4. chucky

    Charging/Maintenance and Alternators

    I would switch/resetable swing gate breakers on each charging source to isolate each one before it gets to the battery ! No need for them to be fighting each other going into 1 set of batteries let one of them be charging on the house batts and 2 as back up to the whole system ! When the trucks...