Isaac
Do the flow timing method with the existing pump. That would discount timing for now. If you swap the 002 pump I would flow test that one too before trying to start in on the 003. You may have to switch timing buttons around. Be sure and record what number button came from the 002 so...
After having the injectors done on my running 003, it will put out 16,800 watts @240 volts (131% indicated load), so far up to an hour with just light fuel smoke. Have not pushed beyond that as my house does not pull that much. Once set up right, they can do it very well. I also might have...
Isaac-I had a 002 do that (start to stall around 70-80% load). Did the Jerry tune on the injectors and little change. Turned out it had a worn IP. Replaced with new from Gimpy and it still runs great....
Is the timing ok? You still should check the valve adjustment though.