  1. mistaken1

    Gen 2 light (again)

    Doesn't the 24V come from the 24V on the fuse panel? Through the orange wire to the gen 2 lamp on the instrument panel. Through the lamp then on the brown/red wire to one of the power contacts (not coil contacts) on the gen 2 relay. Then when the key is on the gen 2 relay is energized so the...
  2. mistaken1

    Gen 2 light (again)

    Shouldn't that brown wire (at the relay) have 24V on it with the key on? The point is you should see 24V to ground at the gen 2 lamp. Perhaps your dash circuit board is bad?
  3. mistaken1

    Gen 2 light (again)

    Right at the relay, what voltages do you read on the brown, brown/red and pink/black wires with the key on and again with the key off? (measure terminal to ground)
  4. mistaken1

    Gen 2 light (again)

    If the drivers side is an isolated ground unit then yes. Isolated ground is stock so unless someone changed the drivers side unit to a civilian case ground unit you will be okay. If you are not sure use your meter to check that the ground terminal is not bonded to the case.