MEP002A Battery Indicator gauge

1800 Diesel

Member
768
26
18
Location
Santa Rosa County, FL
Just lit off an MEP002A & I'm trying to sort out a battery indicator gauge that reads low charge sometimes & other times reads nothing. Batteries are new & are being properly charged at 28.5 volts (per external meter reading across the two batteries with generator running).

Checked the TM and couldn't locate much info on the gauge or wiring. Opened up the control box and see 1 wire going to the gauge through a "rubber grommet". Can someone shed some light on this grommet-looking part in the wiring? Is there a resistor or something inside the rubber? Can the wiring be pulled out of the gauge for testing without damaging anything?

Maybe I just have a bad gauge but wanted to eliminate other causes of the gauge not reading properly while the batteries are being charged at the correct voltage.

Thanks,

Kevin
 

jbk

Member
404
5
16
Location
livingston la.
no resistor in the end of that wire you can pull it straight off. you could use the wiring diagram in the tm to trace were it goes and its condition. my money would be on the gauge ive replaced quiet a few some didnt work at all some were intermident.i get these for $35-$40 in new condition.
 

Jimc

Member
725
1
18
Location
Mullica, nj
yeah i replaced mine. guy on ebay has them in almost brand new condition for about $40 shipped. i do believe the gauge grounds through the mounting bracket so just make sure you dont have some corrosion there. other than that prob a bad gauge.
 

DieselBob

Active member
2,891
15
38
Location
Arnold Maryland
As has been said above it is most likely a bad gauge but checking the ground and the connection on the terminal bar would be a good idea. The feed for the gauge is on TB5-8 in the control box.
 

1800 Diesel

Member
768
26
18
Location
Santa Rosa County, FL
As has been said above it is most likely a bad gauge but checking the ground and the connection on the terminal bar would be a good idea. The feed for the gauge is on TB5-8 in the control box.
Thanks to all who replied. Took the gauge out & cleaned up the mount contact area & also checked voltage at gauge wire after removing (it unscrews) & voltage was 28.7. Reinstalled gauge and ran generator. Gauge is now reading, but staying in the yellow...I know that would be normal if the battery charge was low, but these are fully charged batteries....Saturday, I'll swap out a gauge from another unit before I buy a new one....or maybe Jerry can help me out on a good take-off.... :)

Thanks again for the assist!
 

Isaac-1

Well-known member
1,970
50
48
Location
SW, Louisiana
If you want a marine quality 24V gauge that fits the hole andreads in numerical volt range for the cost of shipping let me know by PM, I bought a lot of 5 or 6 of them for under $10 total a while back on ebay.
 

storeman

Well-known member
1,345
52
48
Location
Mathews County, VA
1800
I have about anything you can think of that's attached to the engine except glow plugs (gone), but nothing left from control boxes except wiring harnesses.
Jerry
 
Top