Bushwacka
Member
- 27
- 0
- 8
- Location
- Smithfield, VA
Guys,
I have a GL Hollingsworth MEP002. After performing all the system checks,reading the TM, I got it started.
The instrument readings percent output is low. Engine running at 1800 RPM. Main breaker is off.
The frequency is: 56-57 hertz but % rated is between15-20 %. Voltage is set at 220v.
What do I adjust to bring up the frequency to 60 hertz and the % to 85-90%?
Thanks,
I have a GL Hollingsworth MEP002. After performing all the system checks,reading the TM, I got it started.
The instrument readings percent output is low. Engine running at 1800 RPM. Main breaker is off.
The frequency is: 56-57 hertz but % rated is between15-20 %. Voltage is set at 220v.
What do I adjust to bring up the frequency to 60 hertz and the % to 85-90%?
Thanks,
Last edited by a moderator: