I recently had a high voltage problem with my MEP-005A and was able to fix it with
help from members of this site. It has been running great since then.
I’m only using between 5%-30% of the generators capacity do I decided to build a load bank
to test the generator and deal with any wet stacking problems that may exist.
The load bank uses a 55 gallon drum and eight 4500 watt 240 volt heating elements capable of 36K watts.
I ran it at 9k watts for a few minutes with no problems.
When I ran it at 18k watts (60%) the engine ran rough and surged as expected
but after about 30 minutes it began running smooth.
The trouble began when I added another 4.5K watts for a total of 22.5K. The best way I can
describe it is it ran for a second then voltage & amperage readings dropped to zero.
A second later it went back up and then dropped to zero a second later.
I let it run like this for a few minutes with no change. There were no error lights.
I added another 4.5k watts for a total of 27k. It continued to cycle on/off.
I added 4.5k watts for a total of 31.5k. It stopped cycling. It actually ran well with some
surging. I was unable to adjust the voltage. It was locked at 111v. I let it run for about 20 minutes.
The surging decreased but the voltage was still locked at 111v.
I couldn’t stop now so I added the remaining 4.5k watt heating element for a total of 36k watts.
I was surprised. It ran very smooth. Frequency was varying about .3 hertz. The voltage is
now 115V and still can’t be adjusted. I let it run for 15 minutes at this power setting and measured
145 amps.
I reduced power to 27K watts and the cycling resumed.
At 18k watts the cycling stopped, it ran extremely well and the voltage was able to be adjusted as usual.
Does anyone have any idea why it would cycle like that and only between about 18k-27k watts?
Also the voltage cannot be adjusted above 18K and locks at some voltage around 115v. It seem like the
regulator is working except for the ability to adjust the voltage.
I attached a video showing it cycling with 27k watts applied to it and one running with 36k watts.
Thanks,
Brian
View attachment Cycling at 27k.mpg
View attachment Running well at 36k.mpg
help from members of this site. It has been running great since then.
I’m only using between 5%-30% of the generators capacity do I decided to build a load bank
to test the generator and deal with any wet stacking problems that may exist.
The load bank uses a 55 gallon drum and eight 4500 watt 240 volt heating elements capable of 36K watts.
I ran it at 9k watts for a few minutes with no problems.
When I ran it at 18k watts (60%) the engine ran rough and surged as expected
but after about 30 minutes it began running smooth.
The trouble began when I added another 4.5K watts for a total of 22.5K. The best way I can
describe it is it ran for a second then voltage & amperage readings dropped to zero.
A second later it went back up and then dropped to zero a second later.
I let it run like this for a few minutes with no change. There were no error lights.
I added another 4.5k watts for a total of 27k. It continued to cycle on/off.
I added 4.5k watts for a total of 31.5k. It stopped cycling. It actually ran well with some
surging. I was unable to adjust the voltage. It was locked at 111v. I let it run for about 20 minutes.
The surging decreased but the voltage was still locked at 111v.
I couldn’t stop now so I added the remaining 4.5k watt heating element for a total of 36k watts.
I was surprised. It ran very smooth. Frequency was varying about .3 hertz. The voltage is
now 115V and still can’t be adjusted. I let it run for 15 minutes at this power setting and measured
145 amps.
I reduced power to 27K watts and the cycling resumed.
At 18k watts the cycling stopped, it ran extremely well and the voltage was able to be adjusted as usual.
Does anyone have any idea why it would cycle like that and only between about 18k-27k watts?
Also the voltage cannot be adjusted above 18K and locks at some voltage around 115v. It seem like the
regulator is working except for the ability to adjust the voltage.
I attached a video showing it cycling with 27k watts applied to it and one running with 36k watts.
Thanks,
Brian
View attachment Cycling at 27k.mpg
View attachment Running well at 36k.mpg