JM923A2
New member
- 19
- 0
- 0
- Location
- Peyton/Colorado
I have searched the forums and found plenty of information about certain electrical parts, the issue is mine went out all at once. I just received my M923A2 from Ft. Riley of which ran when slave jumped by the seller to load onto the flat bed. The truck was shipped directly from Ft. Riley to Colorado with only a fuel stop. When it arrived it had no batteries so we attempted to jump the truck with his trucks 24v System @ up to 4k amps. He said he hopped into the driver side and toggled the battery on. Then moved the toggle to run and let it sit everything was buzzing etc... when he went to start it by turning it further all electrical shutdown and no gauges worked. We attempted to jump the vehicle from the starter and it would spin but not engage the flywheel. I then added batteries and still no indication that electrical is working. I am thinking it is either the Electronic Control Unit, or the Protective Control Box.
Would the entire system refuse to start if either of these units stopped working?
Would the entire system refuse to start if either of these units stopped working?