joelsplace
New member
- 5
- 0
- 0
- Location
- Northlake, TX
I just bought this unit yesterday and am going over it. The first problem I found was the 24V voltage regulator wires were all disconnected but I found a picture here and have it connected. I checked the red marked wire and it didn't have 24V so I traced the wire to the control panel. The circuit board mounted to the right inside surface of the box was completely disconnected. I need a picture of one or a good diagram to reconnect all the wires. I suspect that the board is bad but I have to start somewhere.
The board is marked A2 30554ASSY72-5020 MFR 02032
I'm not even sure it is the correct board because it has tan paint all over it and the generator is all green. I suspect this unit was used for spare parts to fix other units.
I just found this board in one of the manuals. It's the A/C voltage regulator.j
After a bunch of searching and then making this post I found the diagram I needed. I also found out why it isn't connected or at least one reason. All the eyelets on the wires are slightly too large to fit. I guess I'll file them a little...
Thanks!
The board is marked A2 30554ASSY72-5020 MFR 02032
I'm not even sure it is the correct board because it has tan paint all over it and the generator is all green. I suspect this unit was used for spare parts to fix other units.
I just found this board in one of the manuals. It's the A/C voltage regulator.j
After a bunch of searching and then making this post I found the diagram I needed. I also found out why it isn't connected or at least one reason. All the eyelets on the wires are slightly too large to fit. I guess I'll file them a little...
Thanks!
Last edited: