Hey guys,
I have the following situation with the glow plug system:
In my garage it is around plus 10 celsius degree.
1) switch on the ignition
2) PNK/BLK-39B delivers 12V on the glow plug relay, wait light is on, but LT BLU-505 doesn't deliver ground to the glow plug relay. This leads into a not energyzed glow plug relay
3) after some time (15 sec?) the wait light goes out, PNK/BLK-39B still delivers 12V to the glow plug relay, after some seconds wait light begins again to light and LT BLU-505 still doesnt provide ground![Frown :( :(](data:image/gif;base64,R0lGODlhAQABAIAAAAAAAP///yH5BAEAAAAALAAAAAABAAEAAAIBRAA7)
If i ground manually the port (where LT BLU-505 is connected) of the glow pug relay, it energyzes (click) and delivers 12V on the glow plug relay to the port, where ORN-509B, ORN-503B and ORN-503A are connected.
Checked the contuinity of the LT BLU-505 from the glow plug module to the glow plug relay, while LT BLU-505 is disconnected from the relay and its ok.
![E7.jpg E7.jpg](https://www.steelsoldiers.com/data/attachments/520/520781-473af7e38e44546b0c0b4c1947ef0cc0.jpg)
It looks like, the cards logic works, but not the output.
So my question is, is it possible to find out, has the glow plug card a failure or not?
Is it possible to 'debug' or measure each connection of the glow plug card?
Thank you
I have the following situation with the glow plug system:
In my garage it is around plus 10 celsius degree.
1) switch on the ignition
2) PNK/BLK-39B delivers 12V on the glow plug relay, wait light is on, but LT BLU-505 doesn't deliver ground to the glow plug relay. This leads into a not energyzed glow plug relay
3) after some time (15 sec?) the wait light goes out, PNK/BLK-39B still delivers 12V to the glow plug relay, after some seconds wait light begins again to light and LT BLU-505 still doesnt provide ground
If i ground manually the port (where LT BLU-505 is connected) of the glow pug relay, it energyzes (click) and delivers 12V on the glow plug relay to the port, where ORN-509B, ORN-503B and ORN-503A are connected.
Checked the contuinity of the LT BLU-505 from the glow plug module to the glow plug relay, while LT BLU-505 is disconnected from the relay and its ok.
![E7.jpg E7.jpg](https://www.steelsoldiers.com/data/attachments/520/520781-473af7e38e44546b0c0b4c1947ef0cc0.jpg)
It looks like, the cards logic works, but not the output.
So my question is, is it possible to find out, has the glow plug card a failure or not?
Is it possible to 'debug' or measure each connection of the glow plug card?
Thank you
Last edited: