So after looking at the wiring diagram I realized I took measurements on CL2. I went back and re-performed measurements from post 13 and I got 24 volts on all readings.
Steel Soldiers now has a few new forums, read more about it at: New Munitions Forums!
So the float for the gas gauge doesn’t do anything except the gauge. The low fuel light feeds from the funny S shaped pipe with two floats, particularly the lower. But if I remember right, as long as you DONT have the low fuel light then that shouldn’t be your problem.I'm in the process of updating the well plugs. I saw in the wiring diagram the low fuel safety feature so I used rags to put the floats at the full position but that did not effect the fuel pumps. Still nothing in PRIME/RUN
It’s simple. Put fuel in the tank!
I had the same problem recently where I thought I had a big problem because it wouldn’t crank and the pumps wouldn’t come on. Turns out the fuel tank was completely empty and it must have some sort of safety feature.
Sent from my iPhone using Tapatalk
the funny s shaped thing is FL-1 and FL-2So the float for the gas gauge doesn’t do anything except the gauge. The low fuel light feeds from the funny S shaped pipe with two floats, particularly the lower. But if I remember right, as long as you DONT have the low fuel light then that shouldn’t be your problem.
Sent from my iPhone using Tapatalk
OK, now we're narrowing down why you only get 5 volts at S1 2,4,6,8 & 3 when S1 is in Prime/Run.So after looking at the wiring diagram I realized I took measurements on CL2. I went back and re-performed measurements from post 13 and I got 24 volts on all readings.
OK, now we're narrowing down why you only get 5 volts at S1 2,4,6,8 & 3 when S1 is in Prime/Run.
Since you always have 24 volts at both ends of CR1 then there is an issue with getting the 24 volts from CR1 to S1.
Since you have 24 volts at S1 2,4,6,8 with S1 in the OFF and only 5 volts in the Prime/Run position it indicates there is a poor connection in the path from CR1 to S1-2.
Here is the wiring path to get the 24 volts from CR1 to S1-2.
CR1 pin 1 to wire 120B to J6-33
P6-33 to wire 120A to S10-2. (S10 is the Dead Crank Switch)
S10-3 to wire 133A to P7-14
J7-14 to wire 133B to S17-1. S17 is the Emergency Off Switch
S17-2 to wire 135A to CB1-2
CB1-1 to wire 136D to S1-2
To find where the problem is put S1 in Prime/Run, Dead Crank in Normal, EPO switch button out and measure the voltage all along the path above until you get to a point where the voltage drops from 24 volts down to 5 volts.
Do not disconnect J6/P6 or J7/P7 while measuring the voltages. If needed you can skip testing those points and just go to the other end of the wires to/from those connectors for now.
Remove the wires to terminals 7 & 8 of the Voltage Regulator and put tape on each of the lugs so they can't touch anything or each other.... If I want to test the motor out is there a way to disable the generator portion until I can finish my modifications?