Phil,
I guess you are referring to this video here:
If so, well this doesn't work with the MEP's - they are more sophisticated then that.
Btw. is there a chance that the reconnection board is loose in this Generator? A loose or missing reconnection board could cause the same problem as what your experience, since all the Gauges and your Outlet is connecting to the under side off it?
Yup, the cheaper generators rely on the residual magnetism inside the iron core of the rotor to start the power generation sequence, where MEP and many other generators use an excitation circuit to start creating voltage. If the excitation circuit doesn't bring the voltage high enough, the voltage regulator doesn't see enough power and doesn't take over from there.
Spinning a drill works great for cheap consumer generators that have lost residual magnetism, as long as that is the only issue. Trying to induce more current into the gen head than that is a good way to fry them.