ian99rt
New member
- 7
- 5
- 3
- Location
- Naples, FL
Well my awesome MEP-803A's fuel tank gaskets were in need of replacing and I just replaced the smaller no name batteries with $440 worth of Optima 34/78 batteries (currently sitting at 25.3VDC .
I went to test out the Aux fuel pump and put the system to "PRIME & RUN AUX FUEL" without starting the engine. I was holding my finger over the Aux fuel fitting (expecting to feel a vacuum, but did not hear/feal the aux fuel pump running, only the main fuel lift pump I believe was running) when I heard a lovely electronics POP and saw the blue smoke come out of the small electronics box to the right side of the fuel tank that the Low fuel float system connects to.
I removed the box and investigated and found a MOSFET that popped. I had just verified the 2 float switch circuits were working correctly.
From what I can tell this simple circuit board simply converts the 2 float reed switches to a likely higher current signal for the Aux fuel pump relay and low fuel warning system. I'm trying to find a good wiring schematic for the whole genset but can't seem to find it in the TM.
Before I spend $90 on a used one from fleabay is there any other things i should investigate to ensure I don't let all the smoke out of the next one?
I went to test out the Aux fuel pump and put the system to "PRIME & RUN AUX FUEL" without starting the engine. I was holding my finger over the Aux fuel fitting (expecting to feel a vacuum, but did not hear/feal the aux fuel pump running, only the main fuel lift pump I believe was running) when I heard a lovely electronics POP and saw the blue smoke come out of the small electronics box to the right side of the fuel tank that the Low fuel float system connects to.
I removed the box and investigated and found a MOSFET that popped. I had just verified the 2 float switch circuits were working correctly.
From what I can tell this simple circuit board simply converts the 2 float reed switches to a likely higher current signal for the Aux fuel pump relay and low fuel warning system. I'm trying to find a good wiring schematic for the whole genset but can't seem to find it in the TM.
Before I spend $90 on a used one from fleabay is there any other things i should investigate to ensure I don't let all the smoke out of the next one?